The main fields of use for humidity measuring equipment lie in the pharmaceutical and food industries, heating, ventilation and air-conditioning (HVAC) applications as well as drying processes and storage. Measurement of air humidity moreover plays a key role in meteorology, while archives and museums also use data loggers or humidity measuring instruments
The HC2A-SH / HC2A-S3H fulfils the highest demands on measuring accuracy. It measures humidity and temperature and calculates the dew/frost point.
The HC2A-S3 probe is the meteorological probe with a white housing - same specification overall as the HC2A-S probe but with a different filter (larger pore size suitable for meteorological applications). It measures relative humidity and temperature and calculates the dew/frost point.
The HC2A-S / HC2A-S3 is the most versatile probe from rotronic/humidity and forms the basis of the product portfolio. It measures humidity and temperature and calculates the dew/frost point.
The HC2A-SM is the robust probe from rotronic/humidity for harsh environments and adds to the wide product portfolio. It measures humidity and temperature and calculates the dew/frost point.
Miniature rh and temperature probe with digital or analog outputs. Designed for environmental control applications.
rotronic/humidity PC62 & PC62V – Reliable digital relative humidity and temperature probeHighly accurate measurements in precision manufacturing applications.
rotronic/humidity PC33 & PC52 – Stable measurements with analog outputCost-effective probes designed for HVAC and controlled environment applications.
The rotronic/humidity industrial probe is especially suitable for high temperatures and demanding industrial environments. It measures humidity and temperature and calculates the dew/frost point.
The metal industrial probe is especially suitable for high temperatures, demanding industrial environments and areas where hygiene plays an important role. The probe measures humidity and temperature and calculates the dew/frost point.
The rotronic/humidity industrial probe is especially suitable for high temperatures and demanding industrial environments. It measures humidity and temperature and calculates the dew/frost point.
The rotronic/humidity industrial probe is especially suitable for high temperatures up to 200 °C and demanding industrial environments. It measures humidity and temperature and is compatible with the HF5, HF8 series measurement transmitters, HP32 and HP23 handheld devices and the HL-NT dataloggers.
The rotronic/humidity metal industrial probe is especially suitable for high temperatures up to 200 °C and demanding industrial environments and applications where hygiene plays an important role. It measures humidity and temperature and is compatible with the HF5, HF8 series measurement transmitters, HP32 and HP23 handheld devices and the HL-NT dataloggers.
The rotronic/humidity industrial screw-in probe is especially suitable for high temperatures up to 200 °C and demanding industrial environments with applications in which pressures prevail. It measures humidity and temperature and is compatible with the HF5, HF8 series measurement transmitters, HP32 and HP23 handheld devices and the HL-NT dataloggers.
The rotronic/humidity industrial probe is especially suitable for high temperatures up to 200 °C and demanding industrial environments. It measures humidity and temperature and is compatible with the HF5, HF8 series measurement transmitters, HP32 and HP23 handheld devices and the HL-NT dataloggers..
The Probe for Hydrogen Peroxide Environments (H2O2).
The handheld probe is especially suitable for mobile measurements of high temperatures. It measures humidity and temperature and calculates the dew/frost point.
The station probe HC2-AW-USB offers new possibilities. The USB probe can be directly connected to a PC running HW4-P-QUICK-Vx software enabling water activity measurement capability. The HC2-AW-USB is the perfect device for a multi station application, as multiple probes can be attached to a single PC.
The miniature probe is used for humidity and temperature measurement in confined spaces. It also calculates the dew and frost point and can be mounted discretely.
The flush mount probe is installed in the walls of glass cabinets, showcases, laboratories and in clean rooms for humidity and temperature measurement in inconspicuous manner.
The insertion probe is suitable for measurement in dust-free bulk materials, bricks, concrete, etc. It measures humidity and temperature and calculates the dew/frost point.
The insertion probe is suitable for measurement in bulk materials, bricks, concrete, etc. It measures humidity and temperature and calculates the dew/frost point.
HygroClip2 EX screw-in cable probe, cable lengths 2/5/10 metres, with ½“ G/NPT thread
The low dew point probe comes with the latest AirChip4000 technology. Calculates a measurement from the average of 8,000 single points within a 2 second interval and, together with the HYGROMER® LDP-1 dew point sensor, delivers measurements of the highest quality.
The HygroFlex1 series is the latest development in inexpensive HVAC transmitters for relative humidity and temperature. The devices are equipped with the tried-and-tested Hygromer® IN-1 sensor and boast unbeatable value for money. The optional ROTRONIC HW4/SW21 software enables you to change the scale and calibrate and adjust the transmitter.
R-Type / S-Type
Measures relative humidity and temperature and calculates the dew/frost point in offices and rooms where good looks play a role.
W-Type / D-Type
Measures relative humidity and temperature and calculates the dew/frost point in HVAC applications focused on relability and repeatability.
Measures relative humidity and temperature and calculates the dew/frost point in the fields of HVAC and industry.
The HF5-series is the latest development in measurement transmitters for humidity, temperature and dewpoint. The HF5-series is compatible with HygroClip2 series probes with integrated AirChip3000 technology - thanks to which the probes achieve an unparalleled degree of accuracy not seen before
The HF7 transmitter series is designed for fixed installation in industrial applications where conditions are within the range of 0 to 100 %RH and -100 to 150°C (-148 to 302°F). The probe of the HF7 can survive exposure to temperature up to 200°C (392°F). Equipped with a metal enclosure and a metal probe, the HF7 can handle the toughest industrial environments.
The HF73A transmitter series is designed for fixed installation in industrial applications where conditions are within the range of 0 to 100 %RH and -100 to 150°C (-148 to 302°F). The probe of the HF73A can survive exposure to temperature up to 200°C (392°F). Equipped with an aluminum enclosure and a PPS probe, the HF73A can handle the toughest industrial environments.
The HF8 is a multi-function transmitter designed to meet the requirements of applications requiring multiple instruments with one self-contained instrument. The HF8 has an extensive set of optional functions and settings that can be configured and enabled with the rotronic/humidity HW4 software after connecting the HF8 to a PC.
The new HygroFlex5-EX series is the latest development in two-channel transmitters for the exact measurement of humidity and temperature in explosive atmospheres. This device conforms to the latest international standards.
The XB OEM transmitter consists of a cable probe and PCB without housing. Thanks to its compact size, high accuracy and various selection possibilities, the transmitter can be adapted to customer wishes and used everywhere.
The XB OEM transmitter consists of a cable pps probe and PCB without housing. Thanks to its compact size, high accuracy and various selection possibilities, the transmitter can be adapted to customer wishes and used practically everywhere.
The compact data logger for humidity and temperature measurement offers high precision and reliability at a reasonable price. The HL-20 series is easy to use and deployable in a wide range of applications. Thanks to its integrated batteries, the HL-20 works completely independently and offers its users maximum flexibility.
The compact data logger for humidity and temperature measurement offers high precision and reliability at a reasonable price. The HL-20 series is easy to use and deployable in a wide range of applications. Thanks to its integrated batteries, the HL-20 works completely independently and offers its users maximum flexibility.
The HL1D is a compact, low-cost data logger capable of ±3.0 %RH and ±0.3°C accuracy. The internal memory can store up to 32,000 data points and includes the HW4-Lite software. HL-1D Data Logger fulfils the guidelines in accordance with EN 12830.
Barometric pressure, humidity temperature and dew point data logger. Compact, dependable, and inexpensive.
The HygroPalm HP31 is a handheld instrument with a fix rotronic/humidity probe, it is able to perform spot measurements and logging of relative humidity, temperature, and psychrometric parameters.
The HygroPalm HP32 is a versatile handheld instrument compatible with all HC2A and HC2 rotronic/humidity probes, it is able to perform spot measurements and logging of relative humidity, temperature and psychrometric parameters. Simply connect it to the probe input on the top.
The HP-GTS from rotronic/humidity is a tried-and-tested instrument for measurement of equilibrium relative humidity and temperature in stacks of paper and cardboard.
The MP101A is a combined humidity and temperature probe designed primarily for meteorological and general outdoor applications. Operation from DC voltage and low power consumption make the MP101A particularly suitable for operation at remote locations. Energizing of the probe is required for only 0.25 seconds during each measurement. The linear output signals are consistent with the requirements of most data acquisition systems.
The HC2A-S3 probe is the meteorological probe with a white housing - same specification overall as the HC2A-S probe but with a different filter (larger pore size suitable for meteorological applications). It measures relative humidity and temperature and calculates the dew/frost point.
Applications
Weather stations, snow guns, status monitoring of roads, bridges and airports, snow and ice warning systems, research in the wilderness
Snow guns, weather stations, agricultural meteorology, building management systems.
Naturally ventilated shields are used where the natural ventilation (wind) suffices, e.g. measurement stations in the mountains.
Naturally ventilated shields are used where the natural ventilation (wind) suffices, e.g. measurement stations in the mountains.
Naturally ventilated shields are used where the natural ventilation (wind) suffices, e.g. measurement stations in the mountains.
Portable humidity and temperature calibrator. Generates stable humidity and temperature conditions for a wide range of customer set-points. HygroGen2 is a world leading temperature and humidity calibration solution for use both in the laboratory and also on site. Easy to set up and use. Calibrates multiple probes simultaneously (any manufacturer). Time saving, stable and minimal thermal gradients.
Humidity and temperature generators for calibration of humidity and temperature measuring instruments. Calibrates multiple probes simultaneously. Large chamber volume with shelves, up to 8 probes can be calibrated simultaneously, multiple small loggers can be calibrated.
The HygroCal100 provides a stable test chamber to quickly evaluate the performance of relative humidity sensors across a wide range of 5 to 95% relative humidity.
These humidity standards from rotronic/humidity are supplied in packs of 5 hermetically sealed ampoules of the same humidity level. Each ampoule is labelled with the humidity value and a serial number. The values most commonly used are 35 %rH and 80 %rH. These are used for 2-point calibrations. With the exception of the 0 %rH standard the ampoules contain an unsaturated saline solution. For the 0 % standard we use highly porous ceramic material (a molecular sieve). Each set is supplied with an SCS certificate which guarantees the traceability and accuracy of the humidity standards used for calibration purposes.